stillapparel.blogg.se

Cfs software
Cfs software







cfs software

  • ASCE 7-05 issue corrected with ASD check box.
  • Fixed wind export to export max height of wind loads when building taller than 60ft.
  • Corrected issue that corrupted CFS designer file.
  • Wall Stud module optimized to help reduce lag time.
  • Bug in Rafter framing has been fixed that had incorrectly initialized inputs for load combinations.
  • Bug in exporting of members from wall with opening module to beam input for older version files has been fixed.
  • ASCE 7-16 added Partially Open Building to Enclosure Classification.
  • Error saving connection design for R1 in beam input.
  • Updated all outputs to be more concise, consistent and easier to read.
  • Added non-composite 2, 3 and 4 stud configurations to LRFS shearwall and x-brace module.
  • Changed stacked shearwall and stacked x-brace modules to LRFS shearwall and LRFS x-brace.
  • Check Bending and Axial and Bending and Tension are now listed separately in rafter module.
  • Added a negative sign to outward load in rafter module.
  • Added connection selector in floor joist module.
  • Enhanced point load selector in kneewall module.
  • Added interior/exterior condition option to stacked wall module.
  • Added images to member settings for 1-span opening.
  • Added HYS and 150 track leg to Connector Selector.
  • Additional on-screen report for required loads for wall stud module.
  • Import of Wind load to 1-span opening and kneewall modules.
  • Addition of S100-16 w/ S1-18 amendments.
  • Fixed an error with a crash in 1-span opening.
  • Wind load in 1-span and wall stud module fixed to not revert back to default 20psf.
  • Issue with multiple built-up members in 1-span opening not saving proper built-up.
  • Yield strength settings fixed to not reverting to default setting in 1-span opening.
  • Fixed error with wall stud and 1-span opening referring back to initial defaults for load, bracing and connections.
  • Fixed issue with knee-wall not saving connectors.
  • Correct Tension allowable load in beam input and wall stud modules.
  • Capacity 0.018 and 0.027 in Steel Sheet was incorrectly reporting 0 value.
  • 1-Span Opening Module added Required toggle in member summary.
  • Simplified input of Wind module for tall parapets.
  • Kneewalls image was updated to reflect suction as well as pressure loads.
  • Improved formatting for LRFS stacked and shearwall report.
  • Fixed formatting for built up member reports in wall stud and beam input modules.
  • Added warning if 0.7 deflection potentially used incorrectly for wall stud, beam input and 1-span module.
  • cfs software

    Added KL/r value output to onscreen summary and summary reports.Improved speed/response time of 1-span, beam input and wall stud module.Added section image to section properties report.Enhanced workspace report with more user options.Automated load names for rafter and stacked wall module.Enhanced beam input (horizontal orientation) summary report.Added “not bearing on support” connection to beam input and floor joist.Added connections to beam input (horizontal orientation).Add “allowed” to on screen summary in wall stud module.

    cfs software

  • Added labeling to sloped loads in wall stud and beam input.
  • cfs software

    Added member designer to wall stud and beam input.Added option for (2) & (3) non-composite members to wall stud, beam input and 1-span.Improved design time for wall stud, beam input and 1-span opening.Fixed error message for 0.7 wind message for 1-span openings.Fixed error opening output with a back to back member with no lateral load in the wall stud module.Fixed issue with knee-wall module, RCKW attached to structural steel and incorrect flag regarding attached to concrete.Fixed issue with openings and built-up members not updating calculations.Fixed issue for gravity load in wall stud in certain sequence not updating calculations.Fixed issue to ensure Ry kicker reaction always adds induced kicker vertical force to Ry gravity regardless of direction.Fixed capacities for LFRS shear walls and x bracing for non-composite sections.









    Cfs software